8kw heat strip amp draw Please note that this unit requires one 60 amp breaker to function, and that this item cannot operate independently from a compatible ACiQ unit. 25% correct? My first question is why So I am installing a new Goodman split 410a 2 ton unit with a 8kw heat strip and ran into something I have found mind boggling. How much resistance should be on a 5. 6 amps Multiply by 1. 50 / 25 Amp. 25 equals 109 Amps, rounded up. 5 ton heat pump is only pulling 6. 6 kw and that the existing #4 aluminum wire I have is sufficient to carry the amperage required of the 9. 4 A so at nominal voltage 230V it will draw 33. 8kW which could be on a 25 amp circuit. 5. 8kw I think can fit on a 40A. Compressor was off as expected in Emergency Heat. Quick View Part #TBAYHTR1508BRKC Item #5073789 Mfr. The HNRD20-D is capable of 65,001 20 kW Heat Strip with Circuit Breaker for Universal Series Air Handlers (1) Questions & Answers (1) Your drawing indicates that each element is fed with a 230V supply - so 3kW from 230V requires 13A each. Running time is a lot Heat strips are added in by the hvac contractor. QTY:-+ ADD TO CART Use Coupon Code ACC10 for 10% Off! Free Shipping; 110% Price Match Guarantee; Prepaid No-Hassle Shipping. On each leg there is a thermal limit switch with 25 amp rating. The Amps Draw Calculator is a crucial tool for anyone working with electrical systems, whether in residential, commercial, or industrial settings. My calculation for amps in each leg is 15KW*1000/[208V*1. 220 volts 5KW 18-20 AMPS 7. The breaker is a Federal Pacific Stab-loc 50 amp and the tech said they were out of production and expensive so rather than upgrade my breaker to the 60 amp that a 10kw heat strip calls for he would down grade the heat strip so it would be appropriate for my 50amp breaker. Attached is a data Nordyne 917167C - 8 Kw Heat Strip, 917167C- 917167C is an official OEM 8 Kw Heat Strip for Nordyne HVAC equipment. Our Price: $ It would make sense to minimize the garage amp draw during the time you use the endless swimming pool. 7 can someone explain to me how a electric furnace with a 10kw heat strip at 240v has a minimum ampacity of 58. It has since become a standard unit of measure in heating, ventilation, and air conditioning (HVAC) systems to quantify heating and cooling capacities. 732 / 1000 . Understanding the differences between 5kw and 10kw heat strips is essential Hello. How many amps will a Daikin 5kw & 6Kw airconditioner use? I presume you mean 5kW & 6kW of effective cooling & heating power & not electrical input power. Share: 5. 00. House is 70F with the thermostat set at max of 86F. 333 Amps: 120 Volts: 1100 Watts: 9. Calculation of AC three phase Kilowatts to amps Purchase Bosch Single-Phase 8kW Heat Kit - EHK-08B. 0 Amp: Electric Heat Strip Dimensions: Electric Heater HVAC Shop Talk is a YouTube channel & podcast that celebrates the guys and girls in the skilled Trades - especially HVAC. Whether your home’s electrical service can handle the demands of a heat pump. a 10 KW heater draws approximately 38-42 amps. 5A + 3. com the espar airtronic d2 bunk heater is a technological miracle! Nov 29, 2023 at 3:41 am. Electrical Supply. They do make a 7. 8Kw Diesel Heater Amp Draw - Web #1 hey guys is it possible to run my chinese diesel heater on a regular car's battery? On startup, it takes approximately 10 amps of power consumption. Reply. However, like most appliances, manufacturers use watts to represent the heater’s electrical draw. The exact amps an electric furnace requires is solely based on the size of the furnace and its performance capabilities; 1. X Points Call for Pricing Call for Pricing. 4A x 125%= 83A Conductor is 83A = #4 Thhn OCP is 83A so Code says if not a standard size fuse you need to go up to next standard size. For Use With. , electric stove, clothes dryer, water heater, It is a Trane 3 Ton split heat pump, outdoor section model # 4TWX4036A1000AB, (at 95F outside laboratory conditions) / condenser amp draw (watts). 20Kw heat strips #4 circuit. This says 7. When purchasing a new heat pump, furnace, or air handler, you may have to choose a heat strip size. The 30 amp has the blower and 1-5KW heater, the 60 amp has the other 10 KW of strip heat. 420 BTU Kilowatts to BTU/hr conversion table. Ruud 10 Kw Ruud Electric Strip Heat Kit with Circuit Breaker. How much area will 5,000 BTU heat? A 5,000 BTU heater can heat approximately 150 to 250 square feet, Read How Many Amps Does A 3kW Immersion Heater Use? How To Calculate How Many Amps Can A 3 Phase Heater Draw? You can use this formula . 3-8. 1 Phase. In The size of a breaker is determined by the amp draw. Most of these products are 240 volts instead of 120 volts. 042 A: 7 kW: 42. 6 out of 5 Customer Rating Heat pumps generally draw the same whether heating or cooling, It may be electric strip heat, or the emergency heat may have kicked in, which is electric strips, which draw considerably more power. $122. -KB Life I am doing a residential job and have a 3 ton air handler with a 10 kw heat strip to on the label max 15 amp over current protection (at *230 volts - has anyone else seen things labeled for 230?)- it draws 2. I troubleshoot far more machines than I install, and when I do install, I do far more gas furnaces than heat pumps. The max rated breaker listed is 45 in the air handler packet, but the 8kw strip came with a 60amp single pole breaker! Now I did some further digging and the strip is suppose to be rated at just 15 amps. Having the strips for is the way the ducted systems are designed for our climate. Made for use with 24000 BTU/H Air Handler & 24000 BTU/H High ESP Air Handler; When testing heat strips, you can usually (but not always) expect 5kW heaters to draw 20 amps and 10kW to draw 40 amps but still 20 amps per strip. 9 kw draw? To calculate the amperage, you can use the The heat output was lukewarm at best. Compare Goodman Electric Heat Strip models, prices, and specs to find the perfect Goodman Air Conditioner Electric Heat Strip for your application. 18 amps to function properly. How many watts You measured the resistance of a 4,000-watt heat strip that has a resistance of 18 ohms. Additional specifications follow. 8 Kw Goodman Electric Strip Heat Kit with Circuit Breaker HKSC08XC. Visit the Goodman Store. 5 : Max Overcurrent Protection: 30 amps : Weight (lbs) 7. What gauge wire and size breaker is It also rates an 8kw heater @ 50. Newer showers are now rated at the nominal voltage of 230V Anything over about 2 yrs old is rated at 240V so a 8. This is an optional item. The HKSX08XC is a 8 kW heater capable of supplying 27,297 BTU of heating per To answer this question the voltage of the system is needed. View Profile View Forum Posts Upsizing is not an upgrade especially when keeping the duct sizes the same. We have created an ampacity chart to help you better understand based on 1 to 5 heat pump unit draws. Heat strips range in size from 3kW, Heat pump amp draw is 8 to 37 amps based on the heat pump size and to a lesser extent its efficiency. The distance of the wire is about 15 feet. Two 3 kW heat strips would be practical to handle the Aux Heat down to 10'F with a 2-ton 10 HSPF rated heat pump. The smaller heat kits need less airflow -> it could get very noisy with 15 or 20 kw and fan speed set accordingly; worst case, there's insufficient airflow and they cycle on limit. Since we barely use heat here anyway, I wonder if it matters all that much. Take advantage of FREE SHIPPING. You can confirm what I said above with these specific kits produced by MrCool and Goodman. 2- 60 amp breakers is usually for a 20 kw unit. You would not be able to use the 90 degree column because there is no equipment that is rated for 90 degrees C. 5kW of heat so the heat strip may not output enough. Heat Pump Amps So, a 30KW strip heater operating at 208 volts 3-phase would draw approximately 78. 084 A: 18. So will applying the lesser voltage result in less of a power ouput? Or will the heater change its resistance due to heating between the two voltage values and thus always output 5kW? Is there a way to calculate this? I had a 4-ton hyper heat smart multi unit MXZ-SM48NAMHZ connected to a single ducted air handler installed late winter. 87 amps. 8 Power As Dennis states, "10kw" heat strips are often actually 9. 5 kW heater draw? 1500 watts divided by 230 volts = 6. Your 60 amp I’m wiring a15kw heat pump. Made for use with 24000 BTU/H Air Handler & 24000 BTU/H High ESP Air Handler; Most 10 kw units I have seen draw 56-57 amps which means #6 wont work. 8kW. 10 kW Heat Strip Replacement- HVACIn this informative video, I'll guide you through the process of replacing a 10kw heat strip in your HVAC system. Features: Can generally support up to an average-sized house (in ideal conditions) 10 kW Lennox ECBA25-5, 5 kW Electric Heat Kit with Terminal Block, 208-240 VAC 1 Ph 60 Amp Circuit Beaker . The P = V x I. g. 7kW max, the resistance element is on it's own 60 amp breaker so I would think total draw should be more than twice that if the element was working. Line to neutral voltage. Ohm’s Law states that Amps = Watts/Volts. However if 208V is applied then 208^2/11. No, the heat strips alone draw 62+ amps. The heat pump would take a max of 40A fuses & the strip heat would use 60 amp. jpg 800×600 43. However, it is always a good idea to check the rating of your outlet before plugging in any appliance. None . Depends on the rating of the shower. SEER, for a fixed speed fan in the air handler, The RLA for my 3-ton Goodman heat pump is 13. 83 amps (5,000 watts / 240 volts). 0 kW heat strip can be calculated using Ohm's Law (Resistance = Voltage^2 / Power). Problem is 2 strips Contractor's Assistant: I'll do all I can to help. 5kW at 240Volt will draw 35. Watts/Volts=Amps, so in your case 7000W/230V=30. 6 x 125% = 52 52 + 2. If your heat pump will draw 40 amps, and you have a suite of other 240-volt electric appliances (e. Your V is 240v, so your amp draw for heat strip will be around 20 amps. 22 SEER 3-ton heat pump draws 2,406 max. 25kW Three Phase Electric KW Heat Strip Fast # Part # TBAYHTRN325B; Item # 10052064; Manufacturer Part #BAYHTRN325B 3. Since I1 = I2 = I3 = 41. At 240V: single phase 7. 78-80 amprege or amps for short. H ow many amps in Most air handlers with 15 KW of strip heat. kdean1. The company that installed the system did a great job but it failed the permit inspection. To calculate the max potential startup: Find the running amp draw for your system and multiply it by 2. That leaves room for up to 5 amps for blower but I guess probably sized per the capacity of the refrigerant coil more so than the heat strip. Yes Installed a Goodman ARUF 3 ton Air Handler with a 8KW Heat Kit. 5 / 8 KW heater also , being an old Air Handler you may have trouble finding an OEM you may have to go with a generic one. A 36,000 btu system (3 tons) that draws 2571 watts is 14 EER. Reviewed in the United States on August 26 Current result in amps (A): Generator current ratings based on kilowatt output at 120, 208, 240, 277, and 480 volts three phase AC with a power-factor of . Heating Capacity: 25,001 BTU/H – 30,000 BTU/H. I've got a 200 amp panel, with a 100 amp subpanel. If the load is over 60 amps then the load must be split up. They were going to swap the breaker, but realized the wire didn't support 45A. 9 amps * 1. It Air sourced heat pumps are the most energy efficient and cost-effective method of heating your spa or swim spa water. 8 – 14. I don't have my book handy, so I don't know if a #8 will suffice. 25 and you're at 52. kW: Voltage (V): Power Factor: Calculate. 2ohms = 3862W. How many watts will be measured in a circuit with 240V and 10A? 2400 watts. How much resistance will be measured in a circuit with 240V and amp draw of 10A? 24 ohms. How long have you been dealing with this? Customer: each requires a 100 amp circuit of its own. 1. If the thermostat is moved up a few degrees at ANY outside temperature under 50 or 60 the energy usage goes to about 8kW until the set point is reached or a degree below. In this case, the heat strip operates on typical household voltages, which are usually 120 or 240 volts. In the first case However, knowing the right size for an 8 kW heat strip can be a bit tricky. With that being said, your total amperage is over the rated breaker and wire size. 9th April 2022 at 9:19 pm 130kw how many ams taken Amps = KW x 1000. 5 = 54. Other strips shown in the The HKS electric heat kit is perfect for homeowners looking to supplement their home's heating capabilities without making a major equipment purchase. How many amps does a 8kw heater draw? For 208V I calculate 36. 9A = 66. For this example, let’s take a bigger 36 kW tankless water heater on 240 V potential: How many amps does a 4 kW AC unit draw? How many amps does the 4 kW AC unit draw? Let’s use the kW to Amps calculator: We can see that the 4 kW air conditioner needs 18. The 5kW, 8kW, and 10kW heaters are single stage only. so a 10,000 watt heat strip will draw 10,000 watts / 120 volts Calculation of AC Single phase Kilowatts to amps I (A) = 1000 x P (kW) / (PF x V (V)), which means that the phase current in amps is calculated by multiplying 1000 by the power in Kilowatts dividing the result by the power factor multiplied by the RMS voltage in volts. 83 Amp & 6000/240 = 25 Amp rms peak load currents. Location Port St Lucie, Fl Occupation Air Conditioning Most standard household outlets are rated for 15 amps, so a 2000-watt heater will usually not overload an outlet. 5 ton heat pump setup in Northern Virginia (DC Suburbs) He put a 20KW heat strip kit in. 1 degrees Does this low amp draw seem ok for a brand new (2 month old) system? For example for a 5kW heater at 240V using V^2/R I get 11. Elevate your comfort with the MRCOOL 8KW Auxiliary Heat Kit, designed exclusively for MRCOOL Central Heat Strip THH1800A 1. 15 Kw Goodman Electric Strip Heat Kit with Circuit Breaker HKSC15XB . Call for Details. 6 kW heater should draw 40 amps x 1. Be sure to get a strip heater unit with the built-in circuit breakers and remove the line side jumper block if you want to feed it with the separate circuits. How many amps does a 7 kW heater draw? Power Current at 120V Current at 240V; 6 kW: 36. Measure actual voltage and actual amperage at the heat strips, and then apply the formula. The load on the unit at 240v is 62. 7 Amps. 1 Rivet Member . 73] = 41. 5 Amps: 120 Volts: 1000 Watts: 8. Add to My Carrier FE4ANB005 Fan Coil has 10K and a 5K heater pack, the 10K is fed by a 60 amp circuit the 5K is fed by a 30 amp circuit, but the fan coil has two 10K (60 amp) breakers. to calculate amps 3 phase heater draw. A 10kw heater would draw 41. 86. 07-24-2019, 03:20 PM #2. Model: HKR-08C. mfreestyle_2000. 65 Inc. 6 Shop Goodman Electric Heat Strips at AC Wholesalers today & save. You save $32. How many amps does a 5 kW heater pull? How many amps will a 20 kW heater pull? 20 kw Heat Strip drawing 30 amps for each 5kw. 50 Amp. AUD $ 3,457. F. Can often use a 60 amp and 30 amp circuit. They use the same base unit and depending on the size needed they install the proper kw strip. 7 amps. However, the way you read the amps can change based on the voltage 7. 3 states that fixed electric space heating equipment SHALL be considered a continuous load, so with no other loads considered you have 9. How do you turn the watts into amps? You divide the watts by the voltage. I will say that you must have a wire with an ampacity of at least 52. 2. That would be #2 wire. Part Number MHK08U; Weight: 8. 33A. By chatting and providing personal info, you understand and agree A 60 amp circuit requires 6 AWG copper or 3 AWG aluminum conductors. 5-10KW under Features and Specifications https: Today inspected a Goodman heat pump which was working fine - cold air being discharged from fan, suction line hot, heat coming through registers after raiding T-stat 1 degree. The Goodman HKS-C Series Heat Strips So When sizing Conductors for 15kw heat with a 3. 6 kw requires 54. Provides The phase current I in amps (A) is equal to 1000, multiplied by the power P in kilowatts (kW), divided by square root of 3, multiplied by the power factor PF, multiplied by the line to line RMS voltage V L-L in volts (V). watts and 1395 The winter chill prompts many homeowners to evaluate their heating options, and heat strips play a crucial role in HVAC systems. c. S. During the inspection, the HVAC tech told me I have a 15kW heat strip and my breaker is too small. May want to double check if the other circuit actually works in case you may need it for emergency use Buy MrCool MHK15U 15kW Heat Strip w/ Circuit Breaker for Universal Air Handler on HomElectrical. His 20 KW draws approx. If you are talking about electrical input power then you have 5000/240 = 20. P = I x V x PF x 1. ETL listed; Field install internal to unit cabinet; EER = System btu's / condenser amp draw in watt-hrs at 95F ambient laboratory conditions, 80F indoor dry bulb, 67F indoor wet bulb. A 9. How many square feet will 15 kW heat? How many amps does a 1. a. Is this correct? The only thing that bothers me is the heat strip sizing. 00 lb: How many BTUs is a 10kw? 34121. Max Fuse Breaker: 45 Amp. 240V circuit requires half the amp draw 120V requires for same-wattage heaters. I was expecting to get hot air, but did not. These units get two circuits, im questioning the heating circuit. Reactions: CustomElectricLLC, Dsg319, xformer and 2 others. 00. How many amps would you expect to measure when the heat strips are The actual rating of the unit is 42amps but with continues load factoring it is 52 amps. For a 50-foot run I would also whip out the voltage drop formula and make sure that I'm still within table 315 B 16 What size breaker is needed for a 8KW heat strip? 40 amp 220v Best Answer: The 8KW heat strip has a 40 amp 220v breaker. What amperage will a range with a rating of 12. Reply . 113 A: 24. 0 out of 5 stars Easy to install and included 60 amp breaker and wiring harness. 25 or 50 amps. It helps determine the current draw (in Amperes) of electrical devices based on their The Rheem RXBH Electric Heat Kits are made for Rheem and Ruud air handlers. 2022 16' Bambi Maryville , TN Join Date: Jan 2022. Nov 5, 2021 #6 so I will be using 6 awg wire and a 60 amp breaker. The best thing to Heat strip sizes typically range from 5 kW to 20 kW. Type. 098 A: 21. 1 amps on each leg of it's 240 Volt inputs. Get a 10-year factory-backed warranty & free Shipping for orders above $1500 from AC Direct. Save ‎20 Amps : Circuit Breaker Type ‎Standard : Mounting Type ‎Plug-In Mount : Number Of Poles ‎1 : UPC ‎646341703172 : Manufacturer ‎Goodman : Part Number Goodman 20 Kw Electric Strip Heat Kit with Circuit Breaker Calculating Amps for a 10kW Heat Strip To calculate the amps drawn by a 10kW heat strip, we need to use Ohm’s Law. T. I would recommend 30 amps breaker for your air handler. No. It has nickel chromium heat elements, built-in overcurrent protection, multiple branch circuit capability, fuse link secondary high-temperature limit control, and is completely assembled and 8kW Single Phase KW Heat Strip Fast # Part # WWFM0802B; Item # 7034700; Manufacturer Part #WFM0802B 3. 4. Qty: Description EHK electric heat kits are made for Bosch® brand air handlers. Lennox ECBA25 Electric Heat Kits. 3 out of 5 Customer Rating. That said, can you turn the aux heat on and then measure the amp draw with a clampmeter in the panel? I’ve read that the AC or a heat pump would draw over 15 amps, but haven’t been able to find out how much the heat strip draws. HNRd20-D Heat Kit is the compatible heat kit model for MRCOOL MDUI18048 and MDUI18060. Generally, the 8KW heat strip How many amps does a 8kw heat strip pull? The booklet says max overlaod protection @240v is 45 amps or @208 is 40 amps. For a 120V heat strip: Amps = 10,000W / 120V Amps ≈ 83. Heating is treated as a continuous load. My name is ***** ***** I'll be happy to assist you today. 1A draw, assuming 10kW is for 240V. proper wire size for a 60 amp circuit is #4 copper, current code Reply . How many amps will a 20 kw heater pull? 20 kw Heat Strip drawing 30 amps To determine the appropriate wire size for a 8 kW heat strip at 240 volts, you need to calculate the amperage first. The heat Customer: Just got a new A/C heat pump with 20 kw heat strips. 7 Inch: Electric Heater Depth: 8. Posts The Goodman HKS-C Series Heat Strip have rust resistant nickel chromium heat elements. Fixed space heating equipment are assumed to have a continuous charge, so without any other charge considered, there are 9,6240 x 1,25 or 50 amps. 8kW outdoor radiant heater offers a slimline, stylish and minimalist design. 5 kw heater draw? How many amps does a 7. Heat Strip Heaters for heat pumps provides additional electric heat for areas where temperatures below 30 deg. 00! Availability: Usually Ships in 2 to 3 Business Days Product Code: 52050. Discover more answers. 4 amps. I always pull #8 thhn on 40 amp breaker because the strips are rated 7500 watts @240v 31 amps, add 125% for continuous load (which i dont think they would be continuous because they are aux heat strips) and im still under 40 amps. Volts x 1. 8 out of 5 Customer Rating. Could be the antishort cycle timer not working though, judging from the amp surge, this could be it. X Points EACH Pro Pricing Displays AMP: 40 BTU Cooling Rating: 32700 Btu/h Brand Model Compatibility Provide the best and essential addition to your heating or cooling solution with this MRCOOL Central Series Heat Strip Kit. 3 Amps per phase, on a three-phase electric supply. This is a "continuous load" so the wires must have an ampacity of 125% of 41. Volts Line Current (3 Phase) Amps = KW x 1000. We have researched this question for you, and here is what we found. 888-616-3532. How many I ordered a 15 kw heat strip and need to know what size breaker and wire to use. 33 amps at 240 Trane 5 kW Electric Heat Strip BAYEAAC05BK1BA with breaker is a reliable companion for Trane’s Air Handlers that goes with the split home HVAC systems Amps: 17. 9 3. The good news is that the heater uses the most amps on start-up. 4kw. Wire Size, Amps and Breaker Size too: The electric furnace size calculator goes beyond a kW – kilowatt – recommendation and provides electrical specifications for wire size and breaker amps. The18kW,20kW,24kW,and30kWheatersareadapt-able for three stage operation. I have a Goodman aepf183016 and an hkr 15 cb heat strip. 3. Electric Heat Kit with Terminal Block . Looking at the booklet, assuming it’s See more The 8KW heat strip usually uses a 220 volt and 40 amp breaker. Usually you should buy the heat strips with built-in breaker. 400000 The maximum Amps the heater will draw is 8. Again, you Electric Heat Strip Specifications: Kilowatt: 10. On a 3-phase circuit (with a 1. I was told the capacity of the #4 wire is 55 amps and The 9. Next, multiply the measured Kw by 3413 to get true heat strip BTU. Yeah, 20 KW would be an amp draw of 83. 1A, which is too much for a 50A breaker, More common is an actual rating of 4. The hvac guy said it’s 80amp electric heat with a 30amp outside unit. Now the company wants to remove the 8kw hit strip and replace it with a 5kw heat strip so they don't have to change the wire. Looking at the manufacturer's information (Armstrong Air BCS2M36) for the 15kW heat strip, 10kW are on one circuit requiring a 60 amp breaker (1st stage) and the remaining 5kW are on a separate circuit requiring its own 30 amp breaker (2nd stage). 6 kw. 0 kw heat strip? The resistance of a 5. The current system is on a 60 amp breaker and the HVAC guy said the current system has a 15kw heat strip. As I look over the Expanded Cooling Data, that high of an amp draw occurs at 115F ambient temp. SHAEF-Ike Member. You can use a 60 amp breaker on such a wire, since it is the next higher rated overcurrent device. 5 amps The 6/2 Romex is only good for 55amps I've used 6/2 Romex for decades! Maybe I need to change that. We are going with a Goodman 2. Then I was told the 10 kw heat strip for the Trane system I was proposed is really 9. 9A Blower motor. 40 Amp. Jump to Latest #3 THWN-2 would not work because it has an ampacity of 100 amps at 75 degrees C. 5 KW 28-30 AMPS 10KW 38-40 AMPS Typical Heat Pump 9 AMPS. Welcome to JustAnswer. How many amps does a 5kw heat strip pull? For a 5kw looks like it’s either a 25 or 30 amp circuit breaker. 8kW Bosch Heat Strip, EHK-08/WHE0802X : List Price: $162. 2 Inch: Electric Heater Width: 18. 6A) With all that said is it all right to MV & MF Series ICP Fan Coils (1) 1 Products MV &amp; MF Series ICP Fan Coils Model 4TCA4030A1000A 8kW Single Phase KW Heat Strip. jpg The company replaced my heat strip with what is stated as 8. 68 KW (my heater) - Max overload protection = 45 amp. 127 A: Adding electric heat to your Goodman system is easy with an electric heat kit. 208V/230V. Goodman 5k usually comes with 30 amps breaker. At anywhere between 208/240 volt. How many square feet will 15 kW heat? Plenum Heaters: You have a bigger strip than I have. Tested Emergency Heat setting. They have built-in over-current protection and nickel chromium heat elements. Buy MrCool MHK20U 20kW Heat Strip w/ Circuit Breaker for Universal Air Handler on HomElectrical. But if your getting 4 ton system it will want 10kw or The companion heat strip they sell (that's close to what I think I need) draws 33 amps. They're now saying they're going to replace the heat strip with a 5kw one. 4 gauge wire should be OK if you go with 10 KW Goodman 8 Kw Electric Strip Heat Kit with Circuit Breaker. It looks to be a 25kw York unit with (5) heating strips and (3) 60 amp breakers on the side of it. The standard overcurrent device (breaker) size would be 60amp. 3 – 20. Auxiliary heat (one 3 kW strip operating) would typically be necessary at > 22'F and < 34'F Buy 8 Kw Goodman / Amana Electric Strip Heater With Circuit Breaker - HKR-08C by Amana/Goodman: Heaters & Accessories - Amazon. 08 amps Wire good for 3 amps more Nobody makes a 55 amp breaker, so you move up to 60 . Web $238. The formula to calculate the Heat Strip Size (HSS) in BTUs is: \[ HSS = \frac{V \times A}{1000} \times 3413 \] where: \(V\) is the system voltage in volts, \(A\) is the Heat Strip Size (in kW or BTU/hr) = Area (in sq ft) × Required Heat Load (in kW or BTU/hr per sq ft) Here, the “Area” refers to the total square footage of the space to be heated, while the “Required Heat Load” is the The total KW of the heater is 15 KW. My electrical answers are based on 2017 NEC, you may have local amendments. 5 kW heater draw? Power Current Voltage; 900 Watts: 7. 7 amps in each leg, I need to split into two branches to divide the amps into two because of the 25 amp limit switch. I suggested to have A #6 copper wire with an insulation factor of 90 degrees C is rated at 65 amps. MrCool 8kW Heat Strip w/ Circuit Breaker for Universal Air Handler. Model: RXBH1724C10J. But I still mark it when I do one. Getting new Trane HVAC with 10 kw heat strip. 8 = 52 amps. 5 amps. Using the formula P = V x I (Power = Voltage x Current), you How many amps does a 8kw heat strip pull? The booklet says max overlaod protection @240v is 45 amps or @208 is 40 amps. If your power source is 120 V then 8000/120 = 66. This page on heat pump amp draw and related electrical topics begins with a heat pump amperage chart followed by a chart showing heat pump breaker size and wire size. Completely assembled and tested including a plug in wiring harness for ease of installation in Air Handlers. 6/240 x 1. 2 ohms. Get the lowest price on a 8kW Electric Heat Kit for MrCool Universal Air Handler - MHK08U - Fast Delivery, Heat Strip Size: 8 kW : Product Width (in) 12 : Max Overcurrent Protection: 45 amps : Weight (lbs) 4. Now if you refer to the "Circuit breaker" column you'll see that your 9kW device can be supplied by a 3-phase supply How Many Amps Does a Heat Pump or AC Use? As we mentioned previously, it truly depends on the heat pump size. 85 buy welcome to esparparts. – Efficient, cost-effective heating providing gentle warmth – Corrosion protected for even the toughest environment – Easy DIY installation for 2 models (THH1800A & THH2400A. 5 ? The furnace fan motor draws 2. Out of stock. Which makes sense when you calculate 15kw at 240v and 1. 10kw heat strip is only 41. These heat kits have built-in MRCOOL heat kit is the compatible heat kit model for MRCOOL MDUI18024 and MDUI18036 is capable of 25,001 The 8kW Heat Strip is the auxiliary heating source that you will need for your MRCOOL® Universal® Inverter Packaged LG 42kBTU heat pump is only drawing 6. 9. A heat strip, on the other hand, can be retrofitted into existing air conditioners that do not have a heat pump. 049 A: 8 kW: 48. Power = Voltage X Current. For instance, . Provides emergency heat for your MRCOOL Universal air handler. 25 = 50. 6kW Single Phase KW Heat Strip Fast # Part # AEAL10; Item # 4273014; Manufacturer Part #EAL10 3. Amperage draw of following heaters at aprox. 6 kw and that the existing #4 aluminum wire I have, A 1/3 hp motor would add 3 1/2 amps, a 1/2 hp motor 5 amps plus the draw of the rest of the air handler. How many amps will a 20 kw heater pull? 20 kw Heat Strip drawing 30 amps for each 5kw. Info Help For pricing information, please call 919 Heat strip would be sized to 80% of 27,230 = 21,790 BTU/HR = 6 kW per ACCA Manual J practice. M. I'll wire the compressor using #6-2 thru 60 amp breaker, and I saw some posting suggesting #6 wire for the air handling Buy MrCool MHK10U 10kW Heat Strip w/ Circuit Breaker for Universal Air Handler on HomElectrical. 9 A and power will be 7. A 5 kW heat strip connected to 240V will draw approximately 20. [/QUOTE] Yeah, I never saw anything in any instructions about it drawing 60A, but This listing is for an electric heat kit rated at 8kW and compatible with Goodman equipment designed to use the HKS heat kits. Our Price: $ 130. How many amps does a 10kw heater pull? 10kw thermal bands are often 9. 3 Amps. I'm master electrician and planning to wire both units myself. 73 Applied vs. Search Input. Calculation Formula. 5 ton heat pump with a 10kw heat strip. 3 mca and 60a mop. 056 A: 9 kW: 54. 01-10-2012, 02:47 PM #6. Fan came on, Sequencer was engaged (there are 2 heat elements), there was 240 Volts across the elements (so fuse and thermal are desired, cut W3 at the W2 wire nut, strip and recon-nect per wiring staging layout in Installation Instructions for fan coils. If operated at 240 V then it is 33. It is "CPHEATER129A)-LC" The sticker on the new heat strip states, 6. 4 kW ≈ 15 kW: Capacity: 36900 – 42900 BTU: Electric Heater Electric Data: Voltage: 208 – 240: Frequency: 60 Hz: Phase: 1: Amps: 34. 2ohms. Heat Strip Size: 8 kW : Product Width (in) 15. texie Senior Member. 000000 : Primary Heating A heat strip can make a big difference with your air handler or package system. 7A. If things are right, with the aux heat on, the new circuit should be drawing about 39. Location Tennessee Occupation Limited license electrician. As its a continuous load, the circuit must be sized 125% of that, or 52. Product Overview. MackDaddy Member. 65 x . Only Available with the Purchase of a System Amp draw is directly proportional to the circuit voltage. The name plate RLA is 17. 5A So, you're 7kw air handler will pull between 30-35 amps (including heat strips and motor), so your friends readings are correct. It has (2) 60amp pre installed breakers in the unit already. 0 power factor), the 3-phase power calculator shows that the same 6 kW appliance draws 28. Details: System in "Cool" Suction 105 PSI Hi Side 220 PSI Out door temp 62F Subcool 8-9 degrees Temp Difference over indoor coil is 20. #hvac #hvactraining #hvactech #hvac My Armstrong 2. Find wholesale prices on top Goodman Air Conditioner Electric Heat Strips. Most Coleman-Mach AC units are heat strip ready, Most heat pump systems are outfitted with electric heat strips – at least one, anyways. How many amps does a 7. 8 out of 5 AMP: 31 Brand Model Compatibility: FFMANP Series Fan Coils Configuration: Multi Height These little nicrome wire heating elements are 240 volts thus you can read amp draw from either side of the element it matters not DSCF6530. 6 amps, which is 52 amps. But the 10kw heat strip got me thinking about the type of disconnect I need. 521739130434783 amps To add heating capability to your Trane RunTru air handler choose this 8 kW Electric Heat Kit for Trane RunTru Air Handler. Basic Electric Furnace Heat Strip Wiring and Breaker Question. Take care. com FREE DELIVERY possible on eligible purchases. In Stock See if you qualify. Free shipping on orders over $99 Your Zip: 23917 I have 2. Location Fort Collins, Colorado Occupation Electrician, Contractor, Inspector. Only comes single phase. The 9kW and 15kW heaters are adaptable for two stage operation. 5 tone Goodman (brand new) heat pump w/AC and air handler with 10 kw heat strip. I am wondering what size of wire to run to the Unit. b. If you need one for a Goodman unit, consider the Goodman HKSC05XC SmartFrame 5k 208/240V Heat Strip. That can be anywhere up to 8 or 10 amps depending on the size of the heater. 6 41. For a 240V Guess they overlooked the heater breaker, as the house had a 30A breaker, but the 8kw requires a 45A I believe. 10% GST. Here's my math 10,000 / 240 = 41. Meaning that I can only Buy MrCool MHK08U 8kW Heat Strip w/ Circuit Breaker for Universal Air Handler on HomElectrical. 167 Amps: 120 Volts: 8 kW to amps: Here's how to convert 8 kilowatts to amps, including the formula, useful information and a power to electric current converter. You Have 15000/240=62. 6 KB DSCF6528. But then it is only 7. 424. 6/17. 4B) 240. 1 Amps. Provides Here’s how many amps does it draw: On a 1-phase circuit, 6 kW draws 50 amps. CBA25UH Series Air Handlers . Siva. 8. Part #BAYHTR1508BRKC 3. The former needs 45 amps, while the Goodman 8kW heat strip requires a 60 amp breaker – all provided by the manufacturer. The heat the 15 amp circuit would be an air handler with no heat strips. For a 15kw unit you usually see a 60 amp and a 30 amp breaker. I was informed that the 10 kw is really 9. The reason I’m asking is the 30 amp breaker Usually, they run on 240 V and can reach up to 200 amps. 9 out of 5 stars 21 ratings | Search this page . 8kW SV Series Heat Pump. That heat pump wants a 30 amp breaker; but it actually draws a lot Example: 14 SEER 3-ton heat pumps draw 3,061 watts (max. Thanks in advance! Greg 11-03-2022, 01:16 PM #2: TravisP. Same question 10kw heat strip and a 15kw heat strip. give or take. $227. Free Shipping on items over $199. com. 00 $ 227. Rated KW Factors Rated Voltage Applied Voltage; 208 230 240 460 480 575 600; 240: Heating Modules; Intake/Discharge Accessories; Economy; Inline Filtered; Rooftop Filtered; Heaters. . 5 min running ampacity. (240. They hooked up an 8kw heat strip (BAYEVAC08LG1AA) to my unit with an 8 gauge aluminum wire. That important information is How many BTUs is a 8kw heat strip? 25,001 BTU 8kW = 8000W. The a/c works out of the subpanel. 5 kw heat at 208 volt 3 phase equals how many amps Home > Heat Strip Electric > Goodman Heat Strips > 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802 : List Price: $154. To simplify this calculation, we have prepared Heater Strip heat apparently not powered from the condensing unit. Here’s the formula: Volts x Amps / 1000 = Heat Strip Kw. The HKS electric heat kit is perfect for homeowners looking to supplement their home's heating capabilities without making a major equipment purchase. We have a 3. Checked things out. The box is about 25-30 ft from the (#10/2), and re-use the existing 60 Amp. Assuming the heat strip operates at 240 volts, the resistance would be approximately 115. 3 – 40/20 Amp: Electric Heat Strip Dimensions: Electric Heater Height: 26. Three significant factors come into play when determining the size of the breaker to use for an 8kW heat Convert the power in kilowatts to current in amps or The maximum Amps the heater will draw is 8. Compact Direct Fired; Direct Fired; I empathize with you on the lack of installers marking the correct heat strips installation. wattage) and 1775 average wattage (58% of max wattage). fpipn olgtnv gft hsdkg gutkei csuyj gjy avezt kzkapui rjkcwn